Fire Alarm System Archives | Heartz Bangla Ltd.

Fire Alarm System

/Fire Alarm System

Detector Bases

DB-M01 Common Detector Suitable for DI-M910xE Series Detectors and for DC-M910xE series Detectors Download:DB-M01 Common Detector Base DB-01 Common Detector Suitable for DI-910xE Series Detectors and for DC-910xE series Detectors More Products 

By | 2019-02-12T02:43:16+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Conventional Manual Call Point

DC-M9204 Innovation Manual Call Point Feature ☆ Alarming by pressing ☆ Re-settable (non-breaking glass) via special key ☆ Easy 1st terminate and 2nd fix installation ☆ Semi-flush or surface mount installation ☆ Plug-in structure ☆ UL Approved Technical Specifications ☆ Operating Voltage: 24VDC ☆ Operating Current: Standby Current: 0 Alarm Current: 30mA ☆ Operating [...]

By | 2019-02-12T02:42:24+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Conventional Heat Detector

DC-M9103 Conventional Rate of Rise and Fixed Temperature Heat Detector Feature ☆ Reed switch testing ☆ Output terminal for remote indicator available ☆ Rate of rise and fixed temperature, and fixed temperature programmable ☆ Complying with UL 521 Technical Specifications ☆ Operating voltage: 24VDC(16VDC~28VDC) ☆ Operating current: Standby current: 60μA Alarm current:55mA ☆ Sensitivity: Action [...]

By | 2019-02-12T02:42:00+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Conventional Smoke Detector

DC-M9102 Conventional Photoelectric Smoke Detector Feature ☆ Providing for connections to remote indicators ☆ A magnet test available ☆ Standard: UL268 Technical Specifications ☆ Operating voltage: 24VDC(16VDC~28VDC) ☆ Operating current: Standby current: 60μA Alarm current:55mA ☆ Sensitivity Range: 1.23%~3.20% per ft ☆ Operating Environment: Temperature: 0℃ ~+37.8℃ Relative Humidity: 95% ☆ Dimensions: Diameter: 100mm Height: 44.5mm [...]

By | 2019-02-12T02:41:29+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Conventional Combination Heat Photoelectric Smoke Detector

DC-M9101 Conventional Combination Heat Photoelectric Smoke Detector Feature ☆ Reed switch testing. ☆ Remote indicator output available. ☆ 2 levels smoke sensitivities programmable, complies with UL268. Heat part is fixed temperature, complies with UL521. Technical Specifications ☆ Operating voltage: 24VDC(16VDC~28VDC) ☆ Operating current: Standby current: 60μA Alarm current:55mA ☆ Setting of sensitivity and range: [...]

By | 2019-02-12T02:40:39+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Digital Manual Call Point

DI-M9204 Digital Manual Call Point Feature ☆ Re-settable (non-breaking glass) via special key ☆ Advanced digital communication ☆ Electronically addressed ☆ Friendly installation and test ☆ Wiring before termination ☆ Semi-flush mount installation ☆ Optional back-box for surface mount ☆ Stylish pleasing design Technical Specifications ☆ Protection Rating: IP43 ☆ Operating Voltage: 24VDC ☆ Operating Current: [...]

By | 2019-02-12T02:40:17+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Short Circuit Isolator

C-M9503 Loop Isolator Feature ☆ Polarity-sensitive external connections. Inputand output can be used inversely without direction. ☆ Delayed power-up to output end devices, avoids strong transient current when the load is heavy. ☆ Plug-in structure. ☆ Standards: UL864 NFPA [70,72] Technical Specifications ☆ Operating Voltage: 24VDC ☆ Standby Current ≤0.15mA ☆ Capacity: Maximum 70 devices [...]

By | 2019-02-12T02:39:54+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Addressable Output Module

I-M9301 Addressable Output Module Feature ☆ Single output module ☆ Loop powered for dry contact relay output. Additional 24VDC is required for power output ☆ Connection mode can be set by handhold programmer (P-9910B) ☆ Power output line is monitored for cable fault ☆ Electronically addressed ☆ Two part plug-in construction with base mounted termination [...]

By | 2019-02-12T02:39:22+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Addressable Input Module

I-M9300 Addressable Input Module Feature ☆ Single input module suitable for monitoring switch contact of remote equipment or connecting conventional detectors ☆ Loop power for contact input ☆ Used as interface with conventional detectors and additional 24VDC is required ☆ Connection mode can be set by handhold programmer (P-9910B) ☆ Conventional connection is monitored for [...]

By | 2019-02-12T02:38:52+00:00 December 27th, 2018|Fire Alarm System|0 Comments

UL Listed Addressable Heat Detector

DI-M9103 Intelligent Rate of Rise and Fixed Temperature Heat Detector Feature ☆ Address can be set in field. ☆ Fault self-diagnostic. ☆ Rate of rise and fixed temperature, and fixed temperature programmable ☆ Reed switch testing. ☆ Output terminal for remote indicator available. ☆ Complying with UL 521. ☆ Polling LED can be set to [...]

By | 2019-02-12T02:38:28+00:00 December 27th, 2018|Fire Alarm System|0 Comments