Fire Jockey Pump

XBD series fire pumps are a kind of new type fire products researched and developed in full compliance with the state issued-newly standard of GB6245-2006 “Fire pump”, according to the end-user’s practical needs and special using requirements.

Overview

Industrial Fire Protection System Supplier Bangladesh XBD series fire pumps are a kind of new type fire products researched and developed in full compliance with the state issued-newly standard of GB6245-2006

“Fire pump”, according to the end-user’s practical needs and special using requirements.

The inspection of the state fire equipment quality supervising center shows its all kinds of performance indexes are up to or over the standard’s requirements and it earned the certificate for fire state products.

Instruction

1. Application Scope
XBD series fire pumps are mainly used for the fixed fire hydrant fire system; automatic spraying fire system used by all sorts of organs, projects, high-floor buildings etc. and can be transferred with the clear water without solid grain under 100 or its equivalence, also be used for public-used water providing system for fire, living, production, construction and municipality.

2. Using Instruction

Before start:
1. Turning the clutch by hand, there should be no jammed phenomenon at the turner position.
2. Opening the inlet valve and the vent valve, letting the water fill into the pump’s chamber, then closing the vent valve.
3. Clicking the switch of motor, and confirming whether the turning is right or not.

Running:
1. Fully opening the inlet valves, and closing the valves of the outlet pipe.
2. Connecting the power, Opening the valves of the outlet pipe and adjusting the needed working point when the turning velocity is normal.
3. Watching whether there exist abnormities or not, if yes, should the pump be stopped and inspected before re-running.

Stop:
1. After turning off the outlet valves one by one, shutting off the power.
2. Shutting off the inlet valves.
3. If the ambient temperature is below 0, some warm keeping measures should be adopted.

Applications

1. Application Scope
1– Applicable for the XBC series diesel engine fire-fighting pump control made in this Co., and also for the diesel engine fire-fighting pump and diesel generator controls of users.
2– It is applicable for water supply for fire service and emergency water supply.
3– Suitable for the fire-fighting water supply and emergency water supply in storehouse, yard, airport, petroleum and chemical industry, power plant liquefied gas, textile, ship, and oil ship etc. occasions.

2. Using Instruction
1. The height of the machine room should be depended on the equipment’s height and the lifting apparatus, 3-5m ad the effective height in general.
2. To ensure a good ventilation inside of the machine room, the temperature there should not be over 40°C and enough venting temperature holes must be set.
3. When to mount both inlet and outlet pipes of the fire-fighting pump, do not let their weight loading on the pump so as to prevent it against damage and its performance of running from being affected.
4. It is not allowed to mount the control cabinet in the front of the diesel engine’s radiator, otherwise the electric components inside of the cabinet would be affected and not work normally.