Standard Protected Sprinklers | Heartz Bangla Ltd.

Standard Protected Sprinklers

//Standard Protected Sprinklers

Standard Protected Sprinklers

Standard Protected Sprinklers

Standard Response Sprinkler ; It is designed to be used in accordance with regulations. It has a very wide product range and its temperature sensitivity is provided by 5mm glass bulb or solder solder.

Scope of application

– Office Blocks
– Residences and Residences
– Factories
– Libraries
– Light and Medium Hazard Neighborhoods

A – Standard Response Sprinkler

Upright

Standard Protected Sprinkler - Upright

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6), 115 (8.0)
Temperature Sensor: 5mm Glass Bulb
Connection Diameter: ½ 115 NPT – 80) NPT
Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C, 141 ° C, 182 ° C
Surface: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light, Medium and High Hazard
Mounting Type: Parallel to ground or roof pitch
Approvals: FM, UL, ULC, VdS, CE

pendent

Standard Protected Sprinkler - Pendent

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6), 115 (8.0)
Temperature Sensor: 5mm Glass Bulb
Connection Diameter: ½ 115 NPT – 80) NPT
Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C, 141 ° C, 182 ° C
Surface: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light, Medium and High Hazard
Mounting Type: Parallel to ground or roof pitch
Approvals: FM, UL, ULC, VdS, CE

Hidden Type: Pendent

Standard Protected Sprinkler - Hidden Type

K-Factor: 40.3 (2.8), 80 (5.6), 115 (8.0)
Bulb: 5mm Glass
Connection Diameter: ½ NPT – Cam 5 NPT
Temperature: 68 ° C, 79 ° C, 93 ° C
Surface: Brass
Cover Color : Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light and Medium Hazard
Mounting Type: Parallel to ground
Approvals: FM, UL, ULC, VdS, CE

Flush Pendent

Standard Protected Sprinkler - Flush pendent

K-Factor: 80 (5.6)
Temperature Sensor for: Molten Solder-S
Connection diameter: ½ “NPT
Temperature: 74 ° C, 104 ° C
Surface: Chrome, White
Pressure Class: 175psi in
Hazard Class: Light Hazard
Mounting: parallel to the ground
Approvals : FM, UL, ULC, VdS, CE

sidewall

Standard Protected Sprinkler - Sidewall

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6)
Temperature Sensor: 5mm Glass Bulb
Connection Diameter: ½ ası NPT
Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light, Medium and High Danger
Throw: Horizontal – Vertical
Approvals: FM, UL, ULC, VdS, CE

B – Quick Response Sprinkler

Upright

Quick Response Sprinkler - Upright

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6), 115 (8.0)
Temperature Sensors: 3mm Glass Bulb / Melt Solder
Connection Diameter: ½ 5.6 NPT – 4.2 57 NPT
Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light, Medium and High Hazard
Mounting Type: Parallel to ground or roof pitch
Approvals: FM, UL , ULC, VdS, CE

pendent

Quick Response Sprinkler - Pendent

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6), 115 (8.0)
Temperature Sensors: 3mm Glass Bulb / Melt Solder
Connection Diameter: ½ 5.6 NPT – 4.2 57 NPT
Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light, Medium and High Hazard
Mounting Type: Parallel to ground or roof pitch
Approvals: FM, UL , ULC, VdS, CE

Hidden Type: Pendent

Quick Response Sprinkler - Hidden Type Pendent

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6), 115 (8.0), 160 (11.2)
Bulb: 3mm Glass / Melt Solder
Connection Diameter: ½, NPT -, 2.8 NPT
Temperature: 68 ° C , 74 ° C, 93 ° C, 96 ° C
Surface: Brass
Cover Color: Brass, Chrome, White, Black
Pressure Class: 175 ~ 250psi
Hazard Class: Light and Medium Hazard
Mounting Type: Parallel to ground
Approvals: FM, UL, ULC , VdS, CE

Flush Pendent

Quick Response Sprinkler - Flush Pendent

K-Factor: 80 (5.6)
Temperature Sensor : Melt Solder-QR
Connection Diameter: ½ Basınç NPT
Temperature: 74 ° C
Surface: Chrome, White
Pressure Class: 175psi
Hazard Class: Slight Hazard
Mounting Type: Parallel to ground
Approvals: FM, UL , ULC, VdS, CE

sidewall

Quick Response Sprinkler - Sidewall

K-Factor: 40.3 (2.8), 57 (4.2), 80 (5.6) Temperature Sensor: 3mm Glass Bulb / Melt Solder Connection Diameter: ½ Sıcaklık NPT Temperature: 57 ° C, 68 ° C, 79 ° C, 93 ° C , 141 ° C Surface: Brass, Chrome, White, Black Pressure Class:175 ~ 250psi Hazard Class: Light, Medium and High Danger Throw: Horizontal – Vertical Approvals: FM, UL, ULC, VdS, CE 

Hidden Type Sidewall

Quick Response Sprinkler - Hidden Type Sidewall

K-Factor: 80 (5.6) Temperature Sensor : Melt Solder Connection Diameter: ½ gi NPT Temperature: 74 ° C, 104 ° C Surface: Brass Cover Color: Brass, Chrome, White, Black Pressure Class: 175psi Hazard Class: Light Danger Shot Type:Horizontal Approvals: UL, ULC 

More Products 

By | 2019-02-14T08:34:03+00:00 December 20th, 2018|Fire Hydrant|0 Comments

About the Author:

Leave A Comment